* \file <wiced_bt_hci_firmware_upgrade.h>
*
* AIROC HCI Firmware Upgrade
*
* \brief Provides definitions and APIs that exposes HCI Firmware Upgrade
* managed by the Firmware Upgrade library, e.g.
* fw_upgrade_lib. This service can be utilized by peer Firmware Upgrade
* applications to perform a firmware upgrade.
*
*//*****************************************************************************
* Copyright 2016-2024, Cypress Semiconductor Corporation (an Infineon company) or
* an affiliate of Cypress Semiconductor Corporation. All rights reserved.
*
* This software, including source code, documentation and related
* materials ("Software") is owned by Cypress Semiconductor Corporation
* or one of its affiliates ("Cypress") and is protected by and subject to
* worldwide patent protection (United States and foreign),
* United States copyright laws and international treaty provisions.
* Therefore, you may use this Software only as provided in the license
* agreement accompanying the software package from which you
* obtained this Software ("EULA").
* If no EULA applies, Cypress hereby grants you a personal, non-exclusive,
* non-transferable license to copy, modify, and compile the Software
* source code solely for use in connection with Cypress's
* integrated circuit products. Any reproduction, modification, translation,
* compilation, or representation of this Software except as specified
* above is prohibited without the express written permission of Cypress.
*
* Disclaimer: THIS SOFTWARE IS PROVIDED AS-IS, WITH NO WARRANTY OF ANY KIND,
* EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, NONINFRINGEMENT, IMPLIED
* WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Cypress
* reserves the right to make changes to the Software without notice. Cypress
* does not assume any liability arising out of the application or use of the
* Software or any product or circuit described in the Software. Cypress does
* not authorize its products for use in any products where a malfunction or
* failure of the Cypress product may reasonably be expected to result in
* significant property damage, injury or death ("High Risk Product"). By
* including Cypress's product in a High Risk Product, the manufacturer
* of such system or application assumes all risk of such use and in doing
* so agrees to indemnify Cypress against all liability.
*******************************************************************************/
#ifndef WICED_BT_HCI_FIRMWARE_UPGRADE__H
#define WICED_BT_HCI_FIRMWARE_UPGRADE__H
#include "wiced_bt_gatt.h"
#include "wiced_bt_ota_firmware_upgrade.h"
/**
* \defgroup wicedsys AIROC System
*
* \addtogroup group_hci_wiced_firmware_upgrade AIROC HCI Firmware Upgrade
* \ingroup wicedsys
* @{
*
* The AIROC HCI Firmware Upgrade Service is used by peer applications to
* upgrade firmware on AIROC Bluetooth devices over an HCI connection.
*
* \defgroup group_hci_fw_upgrade_macros Macros
* \defgroup group_hci_fw_upgrade_cback_functions Callback Functions
* \defgroup group_hci_fw_upgrade_functions Functions
*/
/**
* \addtogroup group_hci_fw_upgrade_macros
* \{
*/
/* Command definitions for the HCI FW upgrade */
#define WICED_HCI_UPGRADE_COMMAND_PREPARE_DOWNLOAD WICED_OTA_UPGRADE_COMMAND_PREPARE_DOWNLOAD
#define WICED_HCI_UPGRADE_COMMAND_DOWNLOAD WICED_OTA_UPGRADE_COMMAND_DOWNLOAD
#define WICED_HCI_UPGRADE_COMMAND_VERIFY WICED_OTA_UPGRADE_COMMAND_VERIFY
#define WICED_HCI_UPGRADE_COMMAND_FINISH WICED_OTA_UPGRADE_COMMAND_FINISH
#define WICED_HCI_UPGRADE_COMMAND_GET_STATUS WICED_OTA_UPGRADE_COMMAND_GET_STATUS /* Not currently used */
#define WICED_HCI_UPGRADE_COMMAND_CLEAR_STATUS WICED_OTA_UPGRADE_COMMAND_CLEAR_STATUS /* Not currently used */
#define WICED_HCI_UPGRADE_COMMAND_ABORT WICED_OTA_UPGRADE_COMMAND_ABORT
/* firmware upgrade status codes */
#define HCI_FW_UPGRADE_STATUS_STARTED OTA_FW_UPGRADE_STATUS_STARTED
#define HCI_FW_UPGRADE_STATUS_ABORTED OTA_FW_UPGRADE_STATUS_ABORTED
#define HCI_FW_UPGRADE_STATUS_COMPLETED OTA_FW_UPGRADE_STATUS_COMPLETED
#define HCI_FW_UPGRADE_STATUS_VERIFICATION_START OTA_FW_UPGRADE_STATUS_VERIFICATION_START
/* firmware upgrade callback events */
#define HCI_FW_UPGRADE_EVENT_STARTED OTA_FW_UPGRADE_EVENT_STARTED
#define HCI_FW_UPGRADE_EVENT_DATA OTA_FW_UPGRADE_EVENT_DATA
#define HCI_FW_UPGRADE_EVENT_COMPLETED OTA_FW_UPGRADE_EVENT_COMPLETED
/** \} group_hci_fw_upgrade_macros */
#ifdef __cplusplus
extern "C" {
#endif
/**
* \addtogroup group_hci_fw_upgrade_cback_functions
* \{
*/
/** An optional callback to be executed when the Fimware Upgrade state changes.
* The application can register the callback to execute when the client starts,
* aborts or completes the firmware upgrade process. When the firmware
* has been downloaded and verified and before a callback is executed before
* the library restarts. For example, if the application needs to drop all connections.
*
* \param status : firmware upgrade status (see @ref HCI_FW_UPGRADE_STATUS "firmware upgrade status codes")
*
******************************************************************************/
typedef void (wiced_hci_firmware_upgrade_status_callback_t)(uint8_t status);
/** \} group_hci_fw_upgrade_cback_functions */
/**
* \addtogroup group_hci_fw_upgrade_functions
* \{
*/
/******************************************************************************
* Function Name: wiced_hci_fw_upgrade_init
***************************************************************************//**
* \brief alias for wiced_ota_fw_upgrade_init
*
******************************************************************************/
#define wiced_hci_fw_upgrade_init wiced_ota_fw_upgrade_init
/******************************************************************************
* Function Name: wiced_hci_fw_upgrade_is_active
***************************************************************************//**
* \brief alias for wiced_ota_fw_upgrade_is_active.
*
******************************************************************************/
#define wiced_hci_fw_upgrade_is_active wiced_ota_fw_upgrade_is_active
/******************************************************************************
* Function Name: wiced_hci_fw_upgrade_get_new_fw_info
***************************************************************************//**
* \brief Alias for wiced_ota_fw_upgrade_get_new_fw_info.
*
******************************************************************************/
#define wiced_hci_fw_upgrade_get_new_fw_info wiced_ota_fw_upgrade_get_new_fw_info
/******************************************************************************
* Function Name: wiced_hci_fw_upgrade_set_transfer_mode
***************************************************************************//**
* \brief Alias for wiced_ota_fw_upgrade_set_transfer_mode
*
******************************************************************************/
#define wiced_hci_fw_upgrade_set_transfer_mode wiced_ota_fw_upgrade_set_transfer_mode
/******************************************************************************
* Function Name: hci_fw_upgrade_handle_data
***************************************************************************//**
* \brief Data transfer handler
*
* \details The application calls this function to pass data to the firmware upgrade library
*
* \param[in] conn_id Parameter not used for HCI firmware upgrade
* \param[in] data Pointer to data.
* \param[in] len Length of data to write.
*
* \return true Write was successful, otherwise - false.
*
******************************************************************************/
wiced_bool_t ota_fw_upgrade_handle_data(uint16_t conn_id, uint8_t *data, int32_t len);
#define hci_fw_upgrade_handle_data ota_fw_upgrade_handle_data
/******************************************************************************
* Function Name: hci_fw_upgrade_handle_command
***************************************************************************//**
* \brief Firmware upgrade command handler
*
* \details The application calls this function to pass commands to the firmware upgrade library
*
* \param[in] conn_id Parameter not used for HCI firmware upgrade
* \param[in] data Pointer to data command and parameters. The command value is in the first byte of data.
Optional parameters follow.
* \param[in] len Length of data command and parameters.
*
* \return true The handle is a GATT handle, otherwise - false.
*
******************************************************************************/
wiced_bool_t ota_fw_upgrade_handle_command(uint16_t conn_id, uint8_t *data, int32_t len);
#define hci_fw_upgrade_handle_command ota_fw_upgrade_handle_command
/** \} group_hci_fw_upgrade_functions */
#ifdef __cplusplus
}
#endif
#endif /* WICED_BT_HCI_FIRMWARE_UPGRADE__H */